Troubleshooting OSDs¶
Before troubleshooting your OSDs, check your monitors and network first. If
you execute ceph health
or ceph -s
on the command line and Ceph returns
a health status, it means that the monitors have a quorum.
If you don’t have a monitor quorum or if there are errors with the monitor
status, address the monitor issues first.
Check your networks to ensure they
are running properly, because networks may have a significant impact on OSD
operation and performance.
Obtaining Data About OSDs¶
A good first step in troubleshooting your OSDs is to obtain information in
addition to the information you collected while monitoring your OSDs
(e.g., ceph osd tree
).
Ceph Logs¶
If you haven’t changed the default path, you can find Ceph log files at
/var/log/ceph
:
ls /var/log/ceph
If you don’t get enough log detail, you can change your logging level. See Logging and Debugging for details to ensure that Ceph performs adequately under high logging volume.
Admin Socket¶
Use the admin socket tool to retrieve runtime information. For details, list the sockets for your Ceph processes:
ls /var/run/ceph
Then, execute the following, replacing {daemon-name}
with an actual
daemon (e.g., osd.0
):
ceph daemon osd.0 help
Alternatively, you can specify a {socket-file}
(e.g., something in /var/run/ceph
):
ceph daemon {socket-file} help
The admin socket, among other things, allows you to:
List your configuration at runtime
Dump historic operations
Dump the operation priority queue state
Dump operations in flight
Dump perfcounters
Display Freespace¶
Filesystem issues may arise. To display your filesystem’s free space, execute
df
.
df -h
Execute df --help
for additional usage.
I/O Statistics¶
Use iostat to identify I/O-related issues.
iostat -x
Diagnostic Messages¶
To retrieve diagnostic messages, use dmesg
with less
, more
, grep
or tail
. For example:
dmesg | grep scsi
Stopping w/out Rebalancing¶
Periodically, you may need to perform maintenance on a subset of your cluster,
or resolve a problem that affects a failure domain (e.g., a rack). If you do not
want CRUSH to automatically rebalance the cluster as you stop OSDs for
maintenance, set the cluster to noout
first:
ceph osd set noout
Once the cluster is set to noout
, you can begin stopping the OSDs within the
failure domain that requires maintenance work.
stop ceph-osd id={num}
Note
Placement groups within the OSDs you stop will become degraded
while you are addressing issues with within the failure domain.
Once you have completed your maintenance, restart the OSDs.
start ceph-osd id={num}
Finally, you must unset the cluster from noout
.
ceph osd unset noout
OSD Not Running¶
Under normal circumstances, simply restarting the ceph-osd
daemon will
allow it to rejoin the cluster and recover.
An OSD Won’t Start¶
If you start your cluster and an OSD won’t start, check the following:
Configuration File: If you were not able to get OSDs running from a new installation, check your configuration file to ensure it conforms (e.g.,
host
nothostname
, etc.).Check Paths: Check the paths in your configuration, and the actual paths themselves for data and journals. If you separate the OSD data from the journal data and there are errors in your configuration file or in the actual mounts, you may have trouble starting OSDs. If you want to store the journal on a block device, you should partition your journal disk and assign one partition per OSD.
Check Max Threadcount: If you have a node with a lot of OSDs, you may be hitting the default maximum number of threads (e.g., usually 32k), especially during recovery. You can increase the number of threads using
sysctl
to see if increasing the maximum number of threads to the maximum possible number of threads allowed (i.e., 4194303) will help. For example:sysctl -w kernel.pid_max=4194303
If increasing the maximum thread count resolves the issue, you can make it permanent by including a
kernel.pid_max
setting in the/etc/sysctl.conf
file. For example:kernel.pid_max = 4194303
Kernel Version: Identify the kernel version and distribution you are using. Ceph uses some third party tools by default, which may be buggy or may conflict with certain distributions and/or kernel versions (e.g., Google perftools). Check the OS recommendations to ensure you have addressed any issues related to your kernel.
Segment Fault: If there is a segment fault, turn your logging up (if it is not already), and try again. If it segment faults again, contact the ceph-devel email list and provide your Ceph configuration file, your monitor output and the contents of your log file(s).
An OSD Failed¶
When a ceph-osd
process dies, the monitor will learn about the failure
from surviving ceph-osd
daemons and report it via the ceph health
command:
ceph health
HEALTH_WARN 1/3 in osds are down
Specifically, you will get a warning whenever there are ceph-osd
processes that are marked in
and down
. You can identify which
ceph-osds
are down
with:
ceph health detail
HEALTH_WARN 1/3 in osds are down
osd.0 is down since epoch 23, last address 192.168.106.220:6800/11080
If there is a disk
failure or other fault preventing ceph-osd
from functioning or
restarting, an error message should be present in its log file in
/var/log/ceph
.
If the daemon stopped because of a heartbeat failure, the underlying
kernel file system may be unresponsive. Check dmesg
output for disk
or other kernel errors.
If the problem is a software error (failed assertion or other unexpected error), it should be reported to the ceph-devel email list.
No Free Drive Space¶
Ceph prevents you from writing to a full OSD so that you don’t lose data.
In an operational cluster, you should receive a warning when your cluster
is getting near its full ratio. The mon osd full ratio
defaults to
0.95
, or 95% of capacity before it stops clients from writing data.
The mon osd backfillfull ratio
defaults to 0.90
, or 90 % of
capacity when it blocks backfills from starting. The
OSD nearfull ratio defaults to 0.85
, or 85% of capacity
when it generates a health warning.
Changing it can be done using:
ceph osd set-nearfull-ratio <float[0.0-1.0]>
Full cluster issues usually arise when testing how Ceph handles an OSD
failure on a small cluster. When one node has a high percentage of the
cluster’s data, the cluster can easily eclipse its nearfull and full ratio
immediately. If you are testing how Ceph reacts to OSD failures on a small
cluster, you should leave ample free disk space and consider temporarily
lowering the OSD full ratio
, OSD backfillfull ratio
and
OSD nearfull ratio
using these commands:
ceph osd set-nearfull-ratio <float[0.0-1.0]>
ceph osd set-full-ratio <float[0.0-1.0]>
ceph osd set-backfillfull-ratio <float[0.0-1.0]>
Full ceph-osds
will be reported by ceph health
:
ceph health
HEALTH_WARN 1 nearfull osd(s)
Or:
ceph health detail
HEALTH_ERR 1 full osd(s); 1 backfillfull osd(s); 1 nearfull osd(s)
osd.3 is full at 97%
osd.4 is backfill full at 91%
osd.2 is near full at 87%
The best way to deal with a full cluster is to add new ceph-osds
, allowing
the cluster to redistribute data to the newly available storage.
If you cannot start an OSD because it is full, you may delete some data by deleting some placement group directories in the full OSD.
Important
If you choose to delete a placement group directory on a full OSD, DO NOT delete the same placement group directory on another full OSD, or YOU MAY LOSE DATA. You MUST maintain at least one copy of your data on at least one OSD.
See Monitor Config Reference for additional details.
OSDs are Slow/Unresponsive¶
A commonly recurring issue involves slow or unresponsive OSDs. Ensure that you have eliminated other troubleshooting possibilities before delving into OSD performance issues. For example, ensure that your network(s) is working properly and your OSDs are running. Check to see if OSDs are throttling recovery traffic.
Tip
Newer versions of Ceph provide better recovery handling by preventing
recovering OSDs from using up system resources so that up
and in
OSDs are not available or are otherwise slow.
Networking Issues¶
Ceph is a distributed storage system, so it depends upon networks to peer with OSDs, replicate objects, recover from faults and check heartbeats. Networking issues can cause OSD latency and flapping OSDs. See Flapping OSDs for details.
Ensure that Ceph processes and Ceph-dependent processes are connected and/or listening.
netstat -a | grep ceph
netstat -l | grep ceph
sudo netstat -p | grep ceph
Check network statistics.
netstat -s
Drive Configuration¶
A storage drive should only support one OSD. Sequential read and sequential write throughput can bottleneck if other processes share the drive, including journals, operating systems, monitors, other OSDs and non-Ceph processes.
Ceph acknowledges writes after journaling, so fast SSDs are an
attractive option to accelerate the response time–particularly when
using the XFS
or ext4
filesystems. By contrast, the btrfs
filesystem can write and journal simultaneously. (Note, however, that
we recommend against using btrfs
for production deployments.)
Note
Partitioning a drive does not change its total throughput or sequential read/write limits. Running a journal in a separate partition may help, but you should prefer a separate physical drive.
Bad Sectors / Fragmented Disk¶
Check your disks for bad sectors and fragmentation. This can cause total throughput to drop substantially.
Co-resident Monitors/OSDs¶
Monitors are generally light-weight processes, but they do lots of fsync()
,
which can interfere with other workloads, particularly if monitors run on the
same drive as your OSDs. Additionally, if you run monitors on the same host as
the OSDs, you may incur performance issues related to:
Running an older kernel (pre-3.0)
Running a kernel with no syncfs(2) syscall.
In these cases, multiple OSDs running on the same host can drag each other down by doing lots of commits. That often leads to the bursty writes.
Co-resident Processes¶
Spinning up co-resident processes such as a cloud-based solution, virtual machines and other applications that write data to Ceph while operating on the same hardware as OSDs can introduce significant OSD latency. Generally, we recommend optimizing a host for use with Ceph and using other hosts for other processes. The practice of separating Ceph operations from other applications may help improve performance and may streamline troubleshooting and maintenance.
Logging Levels¶
If you turned logging levels up to track an issue and then forgot to turn
logging levels back down, the OSD may be putting a lot of logs onto the disk. If
you intend to keep logging levels high, you may consider mounting a drive to the
default path for logging (i.e., /var/log/ceph/$cluster-$name.log
).
Recovery Throttling¶
Depending upon your configuration, Ceph may reduce recovery rates to maintain performance or it may increase recovery rates to the point that recovery impacts OSD performance. Check to see if the OSD is recovering.
Kernel Version¶
Check the kernel version you are running. Older kernels may not receive new backports that Ceph depends upon for better performance.
Kernel Issues with SyncFS¶
Try running one OSD per host to see if performance improves. Old kernels
might not have a recent enough version of glibc
to support syncfs(2)
.
Filesystem Issues¶
Currently, we recommend deploying clusters with XFS.
We recommend against using btrfs or ext4. The btrfs filesystem has many attractive features, but bugs in the filesystem may lead to performance issues and spurious ENOSPC errors. We do not recommend ext4 because xattr size limitations break our support for long object names (needed for RGW).
For more information, see Filesystem Recommendations.
Insufficient RAM¶
We recommend 1GB of RAM per OSD daemon. You may notice that during normal operations, the OSD only uses a fraction of that amount (e.g., 100-200MB). Unused RAM makes it tempting to use the excess RAM for co-resident applications, VMs and so forth. However, when OSDs go into recovery mode, their memory utilization spikes. If there is no RAM available, the OSD performance will slow considerably.
Old Requests or Slow Requests¶
If a ceph-osd
daemon is slow to respond to a request, it will generate log messages
complaining about requests that are taking too long. The warning threshold
defaults to 30 seconds, and is configurable via the osd op complaint time
option. When this happens, the cluster log will receive messages.
Legacy versions of Ceph complain about old requests
:
osd.0 192.168.106.220:6800/18813 312 : [WRN] old request osd_op(client.5099.0:790 fatty_26485_object789 [write 0~4096] 2.5e54f643) v4 received at 2012-03-06 15:42:56.054801 currently waiting for sub ops
New versions of Ceph complain about slow requests
:
{date} {osd.num} [WRN] 1 slow requests, 1 included below; oldest blocked for > 30.005692 secs
{date} {osd.num} [WRN] slow request 30.005692 seconds old, received at {date-time}: osd_op(client.4240.0:8 benchmark_data_ceph-1_39426_object7 [write 0~4194304] 0.69848840) v4 currently waiting for subops from [610]
Possible causes include:
A bad drive (check
dmesg
output)A bug in the kernel file system (check
dmesg
output)An overloaded cluster (check system load, iostat, etc.)
A bug in the
ceph-osd
daemon.
Possible solutions:
Remove VMs from Ceph hosts
Upgrade kernel
Upgrade Ceph
Restart OSDs
Debugging Slow Requests¶
If you run ceph daemon osd.<id> dump_historic_ops
or ceph daemon osd.<id> dump_ops_in_flight
,
you will see a set of operations and a list of events each operation went
through. These are briefly described below.
Events from the Messenger layer:
header_read
: When the messenger first started reading the message off the wire.throttled
: When the messenger tried to acquire memory throttle space to read the message into memory.all_read
: When the messenger finished reading the message off the wire.dispatched
: When the messenger gave the message to the OSD.initiated
: This is identical toheader_read
. The existence of both is a historical oddity.
Events from the OSD as it prepares operations:
queued_for_pg
: The op has been put into the queue for processing by its PG.reached_pg
: The PG has started doing the op.waiting for \*
: The op is waiting for some other work to complete before it can proceed (e.g. a new OSDMap; for its object target to scrub; for the PG to finish peering; all as specified in the message).started
: The op has been accepted as something the OSD should do and is now being performed.waiting for subops from
: The op has been sent to replica OSDs.
Events from the FileStore:
commit_queued_for_journal_write
: The op has been given to the FileStore.write_thread_in_journal_buffer
: The op is in the journal’s buffer and waiting to be persisted (as the next disk write).journaled_completion_queued
: The op was journaled to disk and its callback queued for invocation.
Events from the OSD after stuff has been given to local disk:
op_commit
: The op has been committed (i.e. written to journal) by the primary OSD.op_applied
: The op has been write()’en to the backing FS (i.e. applied in memory but not flushed out to disk) on the primary.sub_op_applied
:op_applied
, but for a replica’s “subop”.sub_op_committed
:op_commit
, but for a replica’s subop (only for EC pools).sub_op_commit_rec/sub_op_apply_rec from <X>
: The primary marks this when it hears about the above, but for a particular replica (i.e.<X>
).commit_sent
: We sent a reply back to the client (or primary OSD, for sub ops).
Many of these events are seemingly redundant, but cross important boundaries in the internal code (such as passing data across locks into new threads).
Flapping OSDs¶
We recommend using both a public (front-end) network and a cluster (back-end) network so that you can better meet the capacity requirements of object replication. Another advantage is that you can run a cluster network such that it is not connected to the internet, thereby preventing some denial of service attacks. When OSDs peer and check heartbeats, they use the cluster (back-end) network when it’s available. See Monitor/OSD Interaction for details.
However, if the cluster (back-end) network fails or develops significant latency
while the public (front-end) network operates optimally, OSDs currently do not
handle this situation well. What happens is that OSDs mark each other down
on the monitor, while marking themselves up
. We call this scenario
‘flapping`.
If something is causing OSDs to ‘flap’ (repeatedly getting marked down
and
then up
again), you can force the monitors to stop the flapping with:
ceph osd set noup # prevent OSDs from getting marked up
ceph osd set nodown # prevent OSDs from getting marked down
These flags are recorded in the osdmap structure:
ceph osd dump | grep flags
flags no-up,no-down
You can clear the flags with:
ceph osd unset noup
ceph osd unset nodown
Two other flags are supported, noin
and noout
, which prevent
booting OSDs from being marked in
(allocated data) or protect OSDs
from eventually being marked out
(regardless of what the current value for
mon osd down out interval
is).
Note
noup
, noout
, and nodown
are temporary in the
sense that once the flags are cleared, the action they were blocking
should occur shortly after. The noin
flag, on the other hand,
prevents OSDs from being marked in
on boot, and any daemons that