BlueStore Configuration Reference
Devices
BlueStore manages either one, two, or in certain cases three storage devices.
These devices are “devices” in the Linux/Unix sense. This means that they are
assets listed under /dev
or /devices
. Each of these devices may be an
entire storage drive, or a partition of a storage drive, or a logical volume.
BlueStore does not create or mount a conventional file system on devices that
it uses; BlueStore reads and writes to the devices directly in a “raw” fashion.
In the simplest case, BlueStore consumes all of a single storage device. This
device is known as the primary device. The primary device is identified by
the block
symlink in the data directory.
The data directory is a tmpfs
mount. When this data directory is booted or
activated by ceph-volume
, it is populated with metadata files and links
that hold information about the OSD: for example, the OSD’s identifier, the
name of the cluster that the OSD belongs to, and the OSD’s private keyring.
In more complicated cases, BlueStore is deployed across one or two additional devices:
A write-ahead log (WAL) device (identified as
block.wal
in the data directory) can be used to separate out BlueStore’s internal journal or write-ahead log. Using a WAL device is advantageous only if the WAL device is faster than the primary device (for example, if the WAL device is an SSD and the primary device is an HDD).A DB device (identified as
block.db
in the data directory) can be used to store BlueStore’s internal metadata. BlueStore (or more precisely, the embedded RocksDB) will put as much metadata as it can on the DB device in order to improve performance. If the DB device becomes full, metadata will spill back onto the primary device (where it would have been located in the absence of the DB device). Again, it is advantageous to provision a DB device only if it is faster than the primary device.
If there is only a small amount of fast storage available (for example, less than a gigabyte), we recommend using the available space as a WAL device. But if more fast storage is available, it makes more sense to provision a DB device. Because the BlueStore journal is always placed on the fastest device available, using a DB device provides the same benefit that using a WAL device would, while also allowing additional metadata to be stored off the primary device (provided that it fits). DB devices make this possible because whenever a DB device is specified but an explicit WAL device is not, the WAL will be implicitly colocated with the DB on the faster device.
To provision a single-device (colocated) BlueStore OSD, run the following command:
ceph-volume lvm prepare --bluestore --data <device>
To specify a WAL device or DB device, run the following command:
ceph-volume lvm prepare --bluestore --data <device> --block.wal <wal-device> --block.db <db-device>
Note
The option --data
can take as its argument any of the the
following devices: logical volumes specified using vg/lv notation,
existing logical volumes, and GPT partitions.
Provisioning strategies
BlueStore differs from Filestore in that there are several ways to deploy a BlueStore OSD. However, the overall deployment strategy for BlueStore can be clarified by examining just these two common arrangements:
block (data) only
If all devices are of the same type (for example, they are all HDDs), and if
there are no fast devices available for the storage of metadata, then it makes
sense to specify the block device only and to leave block.db
and
block.wal
unseparated. The lvm command for a single
/dev/sda
device is as follows:
ceph-volume lvm create --bluestore --data /dev/sda
If the devices to be used for a BlueStore OSD are pre-created logical volumes,
then the lvm call for an logical volume named
ceph-vg/block-lv
is as follows:
ceph-volume lvm create --bluestore --data ceph-vg/block-lv
block and block.db
If you have a mix of fast and slow devices (for example, SSD or HDD), then we
recommend placing block.db
on the faster device while block
(that is,
the data) is stored on the slower device (that is, the rotational drive).
You must create these volume groups and these logical volumes manually. as The
ceph-volume
tool is currently unable to do so [create them?] automatically.
The following procedure illustrates the manual creation of volume groups and
logical volumes. For this example, we shall assume four rotational drives
(sda
, sdb
, sdc
, and sdd
) and one (fast) SSD (sdx
). First,
to create the volume groups, run the following commands:
vgcreate ceph-block-0 /dev/sda
vgcreate ceph-block-1 /dev/sdb
vgcreate ceph-block-2 /dev/sdc
vgcreate ceph-block-3 /dev/sdd
Next, to create the logical volumes for block
, run the following commands:
lvcreate -l 100%FREE -n block-0 ceph-block-0
lvcreate -l 100%FREE -n block-1 ceph-block-1
lvcreate -l 100%FREE -n block-2 ceph-block-2
lvcreate -l 100%FREE -n block-3 ceph-block-3
Because there are four HDDs, there will be four OSDs. Supposing that there is a
200GB SSD in /dev/sdx
, we can create four 50GB logical volumes by running
the following commands:
vgcreate ceph-db-0 /dev/sdx
lvcreate -L 50GB -n db-0 ceph-db-0
lvcreate -L 50GB -n db-1 ceph-db-0
lvcreate -L 50GB -n db-2 ceph-db-0
lvcreate -L 50GB -n db-3 ceph-db-0
Finally, to create the four OSDs, run the following commands:
ceph-volume lvm create --bluestore --data ceph-block-0/block-0 --block.db ceph-db-0/db-0
ceph-volume lvm create --bluestore --data ceph-block-1/block-1 --block.db ceph-db-0/db-1
ceph-volume lvm create --bluestore --data ceph-block-2/block-2 --block.db ceph-db-0/db-2
ceph-volume lvm create --bluestore --data ceph-block-3/block-3 --block.db ceph-db-0/db-3
After this procedure is finished, there should be four OSDs, block
should
be on the four HDDs, and each HDD should have a 50GB logical volume
(specifically, a DB device) on the shared SSD.
Sizing
When using a mixed spinning-and-solid-drive setup, it is important to make a large enough
block.db
logical volume for BlueStore. The logical volumes associated with
block.db
should have logical volumes that are as large as possible.
It is generally recommended that the size of block.db
be somewhere between
1% and 4% of the size of block
. For RGW workloads, it is recommended that
the block.db
be at least 4% of the block
size, because RGW makes heavy
use of block.db
to store metadata (in particular, omap keys). For example,
if the block
size is 1TB, then block.db
should have a size of at least
40GB. For RBD workloads, however, block.db
usually needs no more than 1% to
2% of the block
size.
In older releases, internal level sizes are such that the DB can fully utilize only those specific partition / logical volume sizes that correspond to sums of L0, L0+L1, L1+L2, and so on--that is, given default settings, sizes of roughly 3GB, 30GB, 300GB, and so on. Most deployments do not substantially benefit from sizing that accommodates L3 and higher, though DB compaction can be facilitated by doubling these figures to 6GB, 60GB, and 600GB.
Improvements in Nautilus 14.2.12, Octopus 15.2.6, and subsequent releases allow for better utilization of arbitrarily-sized DB devices. Moreover, the Pacific release brings experimental dynamic-level support. Because of these advances, users of older releases might want to plan ahead by provisioning larger DB devices today so that the benefits of scale can be realized when upgrades are made in the future.
When not using a mix of fast and slow devices, there is no requirement to
create separate logical volumes for block.db
or block.wal
. BlueStore
will automatically colocate these devices within the space of block
.
Automatic Cache Sizing
BlueStore can be configured to automatically resize its caches, provided that
certain conditions are met: TCMalloc must be configured as the memory allocator
and the bluestore_cache_autotune
configuration option must be enabled (note
that it is currently enabled by default). When automatic cache sizing is in
effect, BlueStore attempts to keep OSD heap-memory usage under a certain target
size (as determined by osd_memory_target
). This approach makes use of a
best-effort algorithm and caches do not shrink smaller than the size defined by
the value of osd_memory_cache_min
. Cache ratios are selected in accordance
with a hierarchy of priorities. But if priority information is not available,
the values specified in the bluestore_cache_meta_ratio
and
bluestore_cache_kv_ratio
options are used as fallback cache ratios.
- bluestore_cache_autotune
Automatically tune the space ratios assigned to various BlueStore caches while respecting minimum values.
- type
bool
- default
true
- see also
- osd_memory_target
When TCMalloc is available and cache autotuning is enabled, try to keep this many bytes mapped in memory. Note: This may not exactly match the RSS memory usage of the process. While the total amount of heap memory mapped by the process should usually be close to this target, there is no guarantee that the kernel will actually reclaim memory that has been unmapped. During initial development, it was found that some kernels result in the OSD’s RSS memory exceeding the mapped memory by up to 20%. It is hypothesised however, that the kernel generally may be more aggressive about reclaiming unmapped memory when there is a high amount of memory pressure. Your mileage may vary.
- type
size
- default
4Gi
- min
896_M
- see also
bluestore_cache_autotune
,osd_memory_cache_min
,osd_memory_base
,osd_memory_target_autotune
- bluestore_cache_autotune_interval
The number of seconds to wait between rebalances when cache autotune is enabled. bluestore_cache_autotune_interval sets the speed at which Ceph recomputes the allocation ratios of various caches. Note: Setting this interval too small can result in high CPU usage and lower performance.
- type
float
- default
5.0
- see also
- osd_memory_base
When TCMalloc and cache autotuning are enabled, estimate the minimum amount of memory in bytes the OSD will need. This is used to help the autotuner estimate the expected aggregate memory consumption of the caches.
- type
size
- default
768Mi
- see also
- osd_memory_expected_fragmentation
When TCMalloc and cache autotuning is enabled, estimate the percentage of memory fragmentation. This is used to help the autotuner estimate the expected aggregate memory consumption of the caches.
- type
float
- default
0.15
- allowed range
[0, 1]
- see also
- osd_memory_cache_min
When TCMalloc and cache autotuning are enabled, set the minimum amount of memory used for caches. Note: Setting this value too low can result in significant cache thrashing.
- type
size
- default
128Mi
- min
128_M
- see also
- osd_memory_cache_resize_interval
When TCMalloc and cache autotuning are enabled, wait this many seconds between resizing caches. This setting changes the total amount of memory available for BlueStore to use for caching. Note that setting this interval too small can result in memory allocator thrashing and lower performance.
- type
float
- default
1.0
- see also
Manual Cache Sizing
The amount of memory consumed by each OSD to be used for its BlueStore cache is
determined by the bluestore_cache_size
configuration option. If that option
has not been specified (that is, if it remains at 0), then Ceph uses a
different configuration option to determine the default memory budget:
bluestore_cache_size_hdd
if the primary device is an HDD, or
bluestore_cache_size_ssd
if the primary device is an SSD.
BlueStore and the rest of the Ceph OSD daemon make every effort to work within this memory budget. Note that in addition to the configured cache size, there is also memory consumed by the OSD itself. There is additional utilization due to memory fragmentation and other allocator overhead.
The configured cache-memory budget can be used to store the following types of things:
Key/Value metadata (that is, RocksDB’s internal cache)
BlueStore metadata
BlueStore data (that is, recently read or recently written object data)
Cache memory usage is governed by the configuration options
bluestore_cache_meta_ratio
and bluestore_cache_kv_ratio
. The fraction
of the cache that is reserved for data is governed by both the effective
BlueStore cache size (which depends on the relevant
bluestore_cache_size[_ssd|_hdd]
option and the device class of the primary
device) and the “meta” and “kv” ratios. This data fraction can be calculated
with the following formula: <effective_cache_size> * (1 -
bluestore_cache_meta_ratio - bluestore_cache_kv_ratio)
.
- bluestore_cache_size
The amount of memory BlueStore will use for its cache. If zero,
bluestore_cache_size_hdd
orbluestore_cache_size_ssd
will be used instead.- type
size
- default
0B
- bluestore_cache_size_hdd
The default amount of memory BlueStore will use for its cache when backed by an HDD.
- type
size
- default
1Gi
- see also
- bluestore_cache_size_ssd
The default amount of memory BlueStore will use for its cache when backed by an SSD.
- type
size
- default
3Gi
- see also
- bluestore_cache_meta_ratio
Ratio of bluestore cache to devote to metadata
- type
float
- default
0.45
- see also
- bluestore_cache_kv_ratio
Ratio of bluestore cache to devote to key/value database (RocksDB)
- type
float
- default
0.45
- see also
Checksums
BlueStore checksums all metadata and all data written to disk. Metadata checksumming is handled by RocksDB and uses the crc32c algorithm. By contrast, data checksumming is handled by BlueStore and can use either crc32c, xxhash32, or xxhash64. Nonetheless, crc32c is the default checksum algorithm and it is suitable for most purposes.
Full data checksumming increases the amount of metadata that BlueStore must store and manage. Whenever possible (for example, when clients hint that data is written and read sequentially), BlueStore will checksum larger blocks. In many cases, however, it must store a checksum value (usually 4 bytes) for every 4 KB block of data.
It is possible to obtain a smaller checksum value by truncating the checksum to one or two bytes and reducing the metadata overhead. A drawback of this approach is that it increases the probability of a random error going undetected: about one in four billion given a 32-bit (4 byte) checksum, 1 in 65,536 given a 16-bit (2 byte) checksum, and 1 in 256 given an 8-bit (1 byte) checksum. To use the smaller checksum values, select crc32c_16 or crc32c_8 as the checksum algorithm.
The checksum algorithm can be specified either via a per-pool csum_type
configuration option or via the global configuration option. For example:
ceph osd pool set <pool-name> csum_type <algorithm>
- bluestore_csum_type
The default checksum algorithm to use.
- type
str
- default
crc32c
- valid choices
none
crc32c
crc32c_16
crc32c_8
xxhash32
xxhash64
Inline Compression
BlueStore supports inline compression using snappy, zlib, lz4, or zstd.
Whether data in BlueStore is compressed is determined by two factors: (1) the compression mode and (2) any client hints associated with a write operation. The compression modes are as follows:
none: Never compress data.
passive: Do not compress data unless the write operation has a compressible hint set.
aggressive: Do compress data unless the write operation has an incompressible hint set.
force: Try to compress data no matter what.
For more information about the compressible and incompressible I/O hints,
see rados_set_alloc_hint()
.
Note that data in Bluestore will be compressed only if the data chunk will be
sufficiently reduced in size (as determined by the bluestore compression
required ratio
setting). No matter which compression modes have been used, if
the data chunk is too big, then it will be discarded and the original
(uncompressed) data will be stored instead. For example, if bluestore
compression required ratio
is set to .7
, then data compression will take
place only if the size of the compressed data is no more than 70% of the size
of the original data.
The compression mode, compression algorithm, compression required ratio, min blob size, and max blob size settings can be specified either via a per-pool property or via a global config option. To specify pool properties, run the following commands:
ceph osd pool set <pool-name> compression_algorithm <algorithm>
ceph osd pool set <pool-name> compression_mode <mode>
ceph osd pool set <pool-name> compression_required_ratio <ratio>
ceph osd pool set <pool-name> compression_min_blob_size <size>
ceph osd pool set <pool-name> compression_max_blob_size <size>
- bluestore_compression_algorithm
The default compressor to use (if any) if the per-pool property
compression_algorithm
is not set. Note thatzstd
is not recommended for BlueStore due to high CPU overhead when compressing small amounts of data.- type
str
- default
snappy
- valid choices
<empty string>
snappy
zlib
zstd
lz4
- bluestore_compression_mode
The default policy for using compression if the per-pool property
compression_mode
is not set.none
means never use compression.passive
means use compression whenclients hint
that data is compressible.aggressive
means use compression unless clients hint that data is not compressible.force
means use compression under all circumstances even if the clients hint that the data is not compressible.- type
str
- default
none
- valid choices
none
passive
aggressive
force
- bluestore_compression_required_ratio
The ratio of the size of the data chunk after compression relative to the original size must be at least this small in order to store the compressed version.
- type
float
- default
0.875
- bluestore_compression_min_blob_size
Chunks smaller than this are never compressed. The per-pool property
compression_min_blob_size
overrides this setting.- type
size
- default
0B
- bluestore_compression_min_blob_size_hdd
Default value of
bluestore compression min blob size
for rotational media.- type
size
- default
8Ki
- see also
- bluestore_compression_min_blob_size_ssd
Default value of
bluestore compression min blob size
for non- rotational (solid state) media.- type
size
- default
64Ki
- see also
- bluestore_compression_max_blob_size
Chunks larger than this value are broken into smaller blobs of at most
bluestore_compression_max_blob_size
bytes before being compressed. The per-pool propertycompression_max_blob_size
overrides this setting.- type
size
- default
0B
- bluestore_compression_max_blob_size_hdd
Default value of
bluestore compression max blob size
for rotational media.- type
size
- default
64Ki
- see also
- bluestore_compression_max_blob_size_ssd
Default value of
bluestore compression max blob size
for non- rotational (SSD, NVMe) media.- type
size
- default
64Ki
- see also
RocksDB Sharding
BlueStore maintains several types of internal key-value data, all of which are stored in RocksDB. Each data type in BlueStore is assigned a unique prefix. Prior to the Pacific release, all key-value data was stored in a single RocksDB column family: ‘default’. In Pacific and later releases, however, BlueStore can divide key-value data into several RocksDB column families. BlueStore achieves better caching and more precise compaction when keys are similar: specifically, when keys have similar access frequency, similar modification frequency, and a similar lifetime. Under such conditions, performance is improved and less disk space is required during compaction (because each column family is smaller and is able to compact independently of the others).
OSDs deployed in Pacific or later releases use RocksDB sharding by default. However, if Ceph has been upgraded to Pacific or a later version from a previous version, sharding is disabled on any OSDs that were created before Pacific.
To enable sharding and apply the Pacific defaults to a specific OSD, stop the OSD and run the following command:
ceph-bluestore-tool \ --path <data path> \ --sharding="m(3) p(3,0-12) O(3,0-13)=block_cache={type=binned_lru} L P" \ reshard
- bluestore_rocksdb_cf
Enables sharding of BlueStore’s RocksDB. When
true
,bluestore_rocksdb_cfs
is used. Only applied when OSD is doing--mkfs
.- type
bool
- default
true
- bluestore_rocksdb_cfs
Definition of BlueStore’s RocksDB sharding. The optimal value depends on multiple factors, and modification is inadvisable. This setting is used only when OSD is doing
--mkfs
. Next runs of OSD retrieve sharding from disk.- type
str
- default
m(3) p(3,0-12) O(3,0-13)=block_cache={type=binned_lru} L=min_write_buffer_number_to_merge=32 P=min_write_buffer_number_to_merge=32
Throttling
- bluestore_throttle_bytes
Maximum bytes in flight before we throttle IO submission
- type
size
- default
64Mi
- bluestore_throttle_deferred_bytes
Maximum bytes for deferred writes before we throttle IO submission
- type
size
- default
128Mi
- bluestore_throttle_cost_per_io
Overhead added to transaction cost (in bytes) for each IO
- type
size
- default
0B
- bluestore_throttle_cost_per_io_hdd
Default bluestore_throttle_cost_per_io for rotational media
- type
uint
- default
670000
- see also
- bluestore_throttle_cost_per_io_ssd
Default bluestore_throttle_cost_per_io for non-rotation (solid state) media
- type
uint
- default
4000
- see also
SPDK Usage
To use the SPDK driver for NVMe devices, you must first prepare your system. See SPDK document.
SPDK offers a script that will configure the device automatically. Run this script with root permissions:
sudo src/spdk/scripts/setup.sh
You will need to specify the subject NVMe device’s device selector with the
“spdk:” prefix for bluestore_block_path
.
In the following example, you first find the device selector of an Intel NVMe SSD by running the following command:
lspci -mm -n -d -d 8086:0953
The form of the device selector is either DDDD:BB:DD.FF
or
DDDD.BB.DD.FF
.
Next, supposing that 0000:01:00.0
is the device selector found in the
output of the lspci
command, you can specify the device selector by running
the following command:
bluestore_block_path = "spdk:trtype:pcie traddr:0000:01:00.0"
You may also specify a remote NVMeoF target over the TCP transport, as in the following example:
bluestore_block_path = "spdk:trtype:tcp traddr:10.67.110.197 trsvcid:4420 subnqn:nqn.2019-02.io.spdk:cnode1"
To run multiple SPDK instances per node, you must make sure each instance uses its own DPDK memory by specifying for each instance the amount of DPDK memory (in MB) that the instance will use.
In most cases, a single device can be used for data, DB, and WAL. We describe this strategy as colocating these components. Be sure to enter the below settings to ensure that all I/Os are issued through SPDK:
bluestore_block_db_path = ""
bluestore_block_db_size = 0
bluestore_block_wal_path = ""
bluestore_block_wal_size = 0
If these settings are not entered, then the current implementation will populate the SPDK map files with kernel file system symbols and will use the kernel driver to issue DB/WAL I/Os.
Minimum Allocation Size
There is a configured minimum amount of storage that BlueStore allocates on an
underlying storage device. In practice, this is the least amount of capacity
that even a tiny RADOS object can consume on each OSD’s primary device. The
configuration option in question--bluestore_min_alloc_size
--derives
its value from the value of either bluestore_min_alloc_size_hdd
or
bluestore_min_alloc_size_ssd
, depending on the OSD’s rotational
attribute. Thus if an OSD is created on an HDD, BlueStore is initialized with
the current value of bluestore_min_alloc_size_hdd
; but with SSD OSDs
(including NVMe devices), Bluestore is initialized with the current value of
bluestore_min_alloc_size_ssd
.
In Mimic and earlier releases, the default values were 64KB for rotational media (HDD) and 16KB for non-rotational media (SSD). The Octopus release changed the the default value for non-rotational media (SSD) to 4KB, and the Pacific release changed the default value for rotational media (HDD) to 4KB.
These changes were driven by space amplification that was experienced by Ceph RADOS GateWay (RGW) deployments that hosted large numbers of small files (S3/Swift objects).
For example, when an RGW client stores a 1 KB S3 object, that object is written
to a single RADOS object. In accordance with the default
min_alloc_size
value, 4 KB of underlying drive space is allocated.
This means that roughly 3 KB (that is, 4 KB minus 1 KB) is allocated but never
used: this corresponds to 300% overhead or 25% efficiency. Similarly, a 5 KB
user object will be stored as two RADOS objects, a 4 KB RADOS object and a 1 KB
RADOS object, with the result that 4KB of device capacity is stranded. In this
case, however, the overhead percentage is much smaller. Think of this in terms
of the remainder from a modulus operation. The overhead percentage thus
decreases rapidly as object size increases.
There is an additional subtlety that is easily missed: the amplification
phenomenon just described takes place for each replica. For example, when
using the default of three copies of data (3R), a 1 KB S3 object actually
strands roughly 9 KB of storage device capacity. If erasure coding (EC) is used
instead of replication, the amplification might be even higher: for a k=4,
m=2
pool, our 1 KB S3 object allocates 24 KB (that is, 4 KB multiplied by 6)
of device capacity.
When an RGW bucket pool contains many relatively large user objects, the effect of this phenomenon is often negligible. However, with deployments that can expect a significant fraction of relatively small user objects, the effect should be taken into consideration.
The 4KB default value aligns well with conventional HDD and SSD devices.
However, certain novel coarse-IU (Indirection Unit) QLC SSDs perform and wear
best when bluestore_min_alloc_size_ssd
is specified at OSD creation
to match the device’s IU: this might be 8KB, 16KB, or even 64KB. These novel
storage drives can achieve read performance that is competitive with that of
conventional TLC SSDs and write performance that is faster than that of HDDs,
with higher density and lower cost than TLC SSDs.
Note that when creating OSDs on these novel devices, one must be careful to apply the non-default value only to appropriate devices, and not to conventional HDD and SSD devices. Error can be avoided through careful ordering of OSD creation, with custom OSD device classes, and especially by the use of central configuration masks.
In Quincy and later releases, you can use the
bluestore_use_optimal_io_size_for_min_alloc_size
option to allow
automatic discovery of the correct value as each OSD is created. Note that the
use of bcache
, OpenCAS
, dmcrypt
, ATA over Ethernet
, iSCSI, or
other device-layering and abstraction technologies might confound the
determination of correct values. Moreover, OSDs deployed on top of VMware
storage have sometimes been found to report a rotational
attribute that
does not match the underlying hardware.
We suggest inspecting such OSDs at startup via logs and admin sockets in order
to ensure that their behavior is correct. Be aware that this kind of inspection
might not work as expected with older kernels. To check for this issue,
examine the presence and value of /sys/block/<drive>/queue/optimal_io_size
.
Note
When running Reef or a later Ceph release, the min_alloc_size
baked into each OSD is conveniently reported by ceph osd metadata
.
To inspect a specific OSD, run the following command:
ceph osd metadata osd.1701 | egrep rotational\|alloc
This space amplification might manifest as an unusually high ratio of raw to
stored data as reported by ceph df
. There might also be %USE
/ VAR
values reported by ceph osd df
that are unusually high in comparison to
other, ostensibly identical, OSDs. Finally, there might be unexpected balancer
behavior in pools that use OSDs that have mismatched min_alloc_size
values.
This BlueStore attribute takes effect only at OSD creation; if the attribute is changed later, a specific OSD’s behavior will not change unless and until the OSD is destroyed and redeployed with the appropriate option value(s). Upgrading to a later Ceph release will not change the value used by OSDs that were deployed under older releases or with other settings.
- bluestore_min_alloc_size
A smaller allocation size generally means less data is read and then rewritten when a copy-on-write operation is triggered (e.g., when writing to something that was recently snapshotted). Similarly, less data is journaled before performing an overwrite (writes smaller than min_alloc_size must first pass through the BlueStore journal). Larger values of min_alloc_size reduce the amount of metadata required to describe the on-disk layout and reduce overall fragmentation.
- type
uint
- default
0
- bluestore_min_alloc_size_hdd
Default min_alloc_size value for rotational media
- type
size
- default
4Ki
- see also
- bluestore_min_alloc_size_ssd
Default min_alloc_size value for non-rotational (solid state) media
- type
size
- default
4Ki
- see also
- bluestore_use_optimal_io_size_for_min_alloc_size
Discover media optimal IO Size and use for min_alloc_size
- type
bool
- default
false
- see also
DSA (Data Streaming Accelerator) Usage
If you want to use the DML library to drive the DSA device for offloading read/write operations on persistent memory (PMEM) in BlueStore, you need to install DML and the idxd-config library. This will work only on machines that have a SPR (Sapphire Rapids) CPU.
After installing the DML software, configure the shared work queues (WQs) with reference to the following WQ configuration example:
accel-config config-wq --group-id=1 --mode=shared --wq-size=16 --threshold=15 --type=user --name="myapp1" --priority=10 --block-on-fault=1 dsa0/wq0.1
accel-config config-engine dsa0/engine0.1 --group-id=1
accel-config enable-device dsa0
accel-config enable-wq dsa0/wq0.1